ICOM-241
RUN mode
If the DIP-switch “PC/Run” is in position “Run”, the program in the ICOM-241
is executed immediately after a reset. Debugging is not possible in this mode.
Program download
A program created with the Tiger software is downloaded into ICOM-241
through the 9-pin Sub-D connector. To download the following has to be done:
Connect a power supply 8-12 V DC (Polarity: Inner contact = minus,
outer contact = plus)
3
Connect ICOM-241 and PC with 9-pin D-Sub cable
Set DIP switch of ICOM-241 to PC mode
Set the reset DIP switch to „Reset“ and back to original position
Start download at the PC.
Serial port 1 / Download DB-9 plug
TXD 2
RXD 3
GND 5
Wilke Technology GmbH • 0241/918900 • http://www.wilke.de/[email protected] 3-3